KIP Dude resident
Joined: 14 Feb 2006 Posts: 164 Location: Outside USA |
Posted: Tue Mar 18, 2008 11:16 am Post subject: More Light Print Issues in Centre of Drawing |
|
|
I have a KIP 3000 with a little over 100,000 sq. on it. I've been chasing a light middle issue for awhile now. I have a new machine in our office and have swapped out the following components and the problem has not gone away... dev. unit, charge and t/s assemblies adn photoreceptor drum. It's wierd, as I run the total grey test pattern the amount of lightness in the centre changes, almost like I'm getting voltage fluctuation. I guess HV power supply is next on the list to check, just looking for additional input. _________________ Everytime something is made idiot proof... the world creates a better idiot! |
|
|
|
|
|
|
|
|
|
|
cezwhat resident
Joined: 24 Aug 2005 Posts: 221 Location: On the Prairie |
Posted: Tue Mar 18, 2008 12:14 pm Post subject: |
|
|
This sounds crazy but I have seen this problem follow the ips unit. I had a KIP3K that was light down the center and swapped IPS units with another 3K and the problem followed the IPS. I found this by accident when I was trouble shooting an IPS system for a blown out mother board.
I did spend some time on the phone with a KIP tech on this and he confirmed the issue over the phone and reccommended a IPS update.
just a ramblin thought from cez _________________ Giv'em hell before they give it to you! |
|
|
|
|
|
|
|
|
|
|
cjwilt doctor
Joined: 24 Jan 2007 Posts: 1041
|
Posted: Tue Mar 18, 2008 2:37 pm Post subject: |
|
|
Just Curious Kip Dude, It is a new style 3000 serial 1051 or the old style serial 1050 ????
Thanks |
|
|
|
|
|
|
|
|
|
|
satgirl dreaming of medical school
Joined: 24 Jul 2007 Posts: 9 Location: San Antonio |
Posted: Tue Mar 18, 2008 3:24 pm Post subject: light middle of copy |
|
|
I have just replaced thr IPS and the problem remains. Help |
|
|
|
|
|
|
|
|
|
|
KIP Dude resident
Joined: 14 Feb 2006 Posts: 164 Location: Outside USA |
Posted: Wed Mar 19, 2008 2:09 am Post subject: |
|
|
It is approximately 1.5 years old. It is a 1050 series 3000. _________________ Everytime something is made idiot proof... the world creates a better idiot! |
|
|
|
|
|
|
|
|
|
|
cjwilt doctor
Joined: 24 Jan 2007 Posts: 1041
|
Posted: Wed Mar 19, 2008 8:39 am Post subject: |
|
|
I would try a developer with a new developer roller in it. I have seen that trying to refurbish the old style (1050) developers can still have problems in the center. Just a thought. |
|
|
|
|
|
|
|
|
|
|
Don Vick dreaming of medical school
Joined: 20 Aug 2007 Posts: 8 Location: KMBS Birmingham, Al |
Posted: Fri Mar 21, 2008 9:24 am Post subject: |
|
|
I had the same problem on a KIP with 150K. I did the PM and a new toner supply roller in the dev unit resolved the problem. _________________ long days and pleasant nights... |
|
|
|
|
|
|
|
|
|
|
Haith medical school freshman
Joined: 02 Jul 2007 Posts: 10 Location: Chesapeake VA |
Posted: Thu Apr 17, 2008 4:54 pm Post subject: |
|
|
I would go with a developer change too, on this issue. |
|
|
|
|
|
|
|
|
|
|
cezwhat resident
Joined: 24 Aug 2005 Posts: 221 Location: On the Prairie |
Posted: Thu Apr 17, 2008 7:54 pm Post subject: |
|
|
After rereading this string of posts I would have to agree with Don I had the same issue and the supply roller fixed it for me |
|
|
|
|
|
|
|
|
|
|
KIPDOCTOR Site Admin
Joined: 31 Dec 1969 Posts: 1408 Location: Boston Area |
Posted: Fri Apr 18, 2008 6:43 am Post subject: |
|
|
While these units like all other HDP developer units are refreshable, sometimes the supply or the developer roller can be worn beyond it's useful life and will have to be replaced. This is exactly the reason why we put a digital micrometer on every roller on every dev unit we refresh. If a roller is worn beyond use, we will not refresh that unit as it would not last as long as we would llike to see out of it. _________________ What we have gained in technology, we have lost in humanity. |
|
|
|
|
|
|
|
|
|
|
satgirl dreaming of medical school
Joined: 24 Jul 2007 Posts: 9 Location: San Antonio |
Posted: Fri Apr 18, 2008 1:54 pm Post subject: light center of 3000 |
|
|
I know that this may sound crazy but I added the patch 6.5.398 to my customers controller and the light 6 inch center went dark again. I had a rebuild kit with me to correct our problem because I was told that the kit was the only way to fix the problem. Try the patch before you spend 800.00 on parts. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|