actrepro intern
Joined: 19 Jun 2006 Posts: 139 Location: Des Moines, Iowa |
Posted: Wed Aug 22, 2007 3:50 pm Post subject: solid white line |
|
|
have a solid white line from lead to trail edge about 1/3 of the way into the image
cleaned the LED print head
didnt help |
|
|
|
|
|
|
|
|
|
|
Pops777 dreaming of medical school
Joined: 10 Aug 2007 Posts: 5
|
Posted: Tue Sep 04, 2007 2:08 pm Post subject: Clean up, Isle 3! |
|
|
Just a suggestion, I had similar problems, and we cleaned the rollers... maybe that'll help you as well. _________________ - CAD @ CW Howe |
|
|
|
|
|
|
|
|
|
|
actrepro intern
Joined: 19 Jun 2006 Posts: 139 Location: Des Moines, Iowa |
Posted: Wed Sep 05, 2007 11:50 am Post subject: |
|
|
not quite sure what rollers you are talking about
have replaced the supply and devo rollers
drum is new
cant seem to get the print quality back plus the white line issue
thanks |
|
|
|
|
|
|
|
|
|
|
actrepro intern
Joined: 19 Jun 2006 Posts: 139 Location: Des Moines, Iowa |
Posted: Wed Sep 05, 2007 2:53 pm Post subject: |
|
|
does anyone think that the led assy might be bad?
causing this solid white line |
|
|
|
|
|
|
|
|
|
|
MyFirstPlotter medical school freshman
Joined: 11 Aug 2006 Posts: 13
|
Posted: Thu Sep 06, 2007 11:01 pm Post subject: |
|
|
Is this only on prints or on copies or on both? A little more info on when it is happening and where on the sheet it is. Is it only on 30 inch or 36.
Thanks |
|
|
|
|
|
|
|
|
|
|
actrepro intern
Joined: 19 Jun 2006 Posts: 139 Location: Des Moines, Iowa |
Posted: Fri Sep 07, 2007 1:01 pm Post subject: |
|
|
the scanner has been eliminated
it shows up all the time prints and copies
been printing the test prints from the service mode
happens on both paper sizes - and it shows up on the drum
it has a new corona wire, tried a new dev roller, cleaned and cleaned the led, but no luck
on a 36" it shows up about 1/3 in from the left |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|