Home of the Kip Doctor!
REGISTER: In order to register for our forums please send an E mail to [email protected] stating what user name and password you would like. This is now required due to all the spambots that have been registering.
|
KeepItPrinting.com The "unofficial' and "unauthorized" KIP info site.
|
|
|
|
|
|
|
|
|
|
|
RMS intern
Joined: 05 Sep 2006 Posts: 111
|
Posted: Mon Apr 02, 2007 12:45 pm Post subject: GRAY SCALE VERY LIGHT!! |
|
|
CUSTOMER HAS HAD A PAPER JAM RECENTLY AND THEY JERKED THE JAM OUT. IN THE PROCESS SOME HOW THEY MANAGED TO RIP THE CHARGE GRID OFF OF THE CHARGE UNIT. REPLACE CHARGE GRID, TENSION BLOCK AND NEW CORONA WIRE. NO DAMAGE TO THE DRUM BUT NOW ALL THE GRAY SCALES ARE VERY VERY LIGHT. CUSTOMER HAS THE SETTINGS AT THE DARKEST, AND THE GRAY SCALE IS VERY FAINT. AT THIS POINT I HAVE CHEKED ALMOST EVRYTHING I CAN THINK OF. ANY HELP WOULD BE APPRECIATED. |
|
|
|
|
|
|
|
|
|
|
RMS intern
Joined: 05 Sep 2006 Posts: 111
|
Posted: Tue Apr 03, 2007 6:38 pm Post subject: |
|
|
PROBLEM WAS FROM CHARGE GRID GROUNDING OUT AND CAUSING A BAD CONNECTIONS TO GROUND STRAP ON RT. SIDE OF DRUM. DID NOTICE SOME SIGNS OF ARCING. CLEANED AREA VERY WELL AND REGREASED CONTACTS. PRINTS ARE GREAT NOW. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|