Posted: Tue Sep 24, 2013 12:33 pm Post subject: 7100 edge haze |
|
|
I have a 7100 with backround "smudge/haze?" picture will not show from camera so I'll describe as best I can.
Only down 36" left side light haze about an inch wide, looking real close some slight dotted vertical line. while the haze fades mildly darker and lighter continuously down left edge there is no consistancy in the spacing of the fading from lighter to darker. Really close inspection shows some speckle up to 6 inches in from left edge.
Corona charge wire new, all corona assemblies cleaned. Checked drum, fuser, dev. roller and blade for build up or abnormalities.
I took along the most experienced Kip Tech on staff and so far we are stumped.
Ideas? |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Tue Sep 24, 2013 1:36 pm Post subject: |
|
|
Look at resetting the developer bias setting. I find that the auto density control is bumping up the bias to fast and will cause this same type issue. |
|
|
|
|
|
|
|
|
|
|
scott doctor
Joined: 06 Dec 2004 Posts: 570
|
Posted: Wed Sep 25, 2013 11:59 am Post subject: |
|
|
Make sure the drum end blocks are locked down correctly. Check the printhead shims are all there and not bent. Check corona wire heights. Check developer unit roller pressure. _________________ Any ideas expressed are figments of my imagination.
Any resemblance to reality is purely coincidental. |
|
|
|
|
|
|
|
|
|
|
CLUCKAU medical school grad
Joined: 12 Feb 2013 Posts: 85 Location: Utah |
Posted: Tue Oct 01, 2013 4:17 pm Post subject: |
|
|
Thanks as always for the suggestions.
The options for BIAS were 0-3. It was set at 3. 0 seems to have cleaned up the issue, there still remains a very faint dotted line bout a half inch in. But it is faint enough to be acceptable. |
|
|
|
|
|
|
|
|
|
|
tech2tech doctor
Joined: 04 Mar 2005 Posts: 377
|
Posted: Wed Oct 09, 2013 6:58 pm Post subject: |
|
|
You may need to reseat the regulation roller to the developer roller. I had this issue on the right side and that resolved my problem. |
|
|
|
|
|
|
|
|
|
|
CLUCKAU medical school grad
Joined: 12 Feb 2013 Posts: 85 Location: Utah |
Posted: Wed Oct 16, 2013 1:58 pm Post subject: |
|
|
We had re-pressurized the developer rollers and set bias at 0.
Seemed good, the next week got a call that it was now printing light on the left edge.
So I tried setting the bias to 1, it got darker but also brought back some edge smudge/haze.
Any more ideas? |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Wed Oct 16, 2013 2:05 pm Post subject: |
|
|
I found when you are pressurizing the dev on the 7100 you have to follow the steps exactly as in the manual. |
|
|
|
|
|
|
|
|
|
|
CLUCKAU medical school grad
Joined: 12 Feb 2013 Posts: 85 Location: Utah |
Posted: Mon Mar 31, 2014 5:09 pm Post subject: |
|
|
After reading a posting from Mark about removing the rear left filter from all his 8000's for similar issues, I tried it on this 7100 about a month ago.
So far no more complaints.
Thanks Mark! |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Mon Mar 31, 2014 6:11 pm Post subject: |
|
|
Alert the media.....I got one!!!!! _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
adcart8 medical school freshman
Joined: 16 Apr 2018 Posts: 11
|
Posted: Wed Apr 29, 2020 11:35 am Post subject: Haze on Left Side and DOts |
|
|
Yes I definitely would adjust the Bias back down to 0 and then look at the far side of the Drum associated with the DOTS. I have seen a toner leak from a Developer slowly wear down the side of the Drum that it was leaking on. First thing that appears is HAZE and then if you can get rid of the HAZE you are left with DOTS. Just have to replace the Drum! We ran our 24x36 on 24" rolls or another machine until we could justify replacing the Drum. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|