Home of the Kip Doctor!
REGISTER: In order to register for our forums please send an E mail to [email protected] stating what user name and password you would like. This is now required due to all the spambots that have been registering.
|
KeepItPrinting.com The "unofficial' and "unauthorized" KIP info site.
|
|
|
|
|
|
|
|
|
|
|
RLE medical school freshman
Joined: 27 Oct 2006 Posts: 24
|
Posted: Wed Oct 04, 2017 7:17 pm Post subject: 3000 image quality |
|
|
One half the print or copy is entirely black, the other half has heavy vertical lines that a charge assembly would produce, but extremely heavy.
Cleaned the Charge unit, the wire and end blocks are in very good shape, replaced the HV pack and the developer unit. |
|
|
|
|
|
|
|
|
|
|
slyman doctor
Joined: 23 Apr 2008 Posts: 467 Location: Sherbrooke,Quebec |
Posted: Fri Oct 06, 2017 5:17 pm Post subject: |
|
|
Replace the grid and/or the whole charge corona unit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|