Posted: Tue Jun 27, 2017 5:45 pm Post subject: E-03 KIP 7000 |
|
|
Getting a constant E-03 on this old HDP 7000. Have replaced Main Motor, Main Motor Driver Board and Main DC Controller. Have checked all DC Power Supplies, all good. This one has me stumped. Anyone out there with some help for me, please? |
|
|
|
|
|
|
|
|
|
|
bigal doctor
Joined: 17 Apr 2007 Posts: 352 Location: TEXAS |
Posted: Tue Jun 27, 2017 6:19 pm Post subject: E03 |
|
|
Have you checked to see if any binding (mechanical) in the main drive system?
Maybe bearings , belt slipping etc. |
|
|
|
|
|
|
|
|
|
|
caltech doctor
Joined: 24 Feb 2006 Posts: 262 Location: Northern California |
Posted: Tue Jun 27, 2017 6:28 pm Post subject: |
|
|
Yes, I'm running it now with the main motor belt removed so it is only the motor driving. If I mask the error I can run the motor fine in service mode. The motor runs fine then, unmask the error returns. |
|
|
|
|
|
|
|
|
|
|
bigal doctor
Joined: 17 Apr 2007 Posts: 352 Location: TEXAS |
Posted: Tue Jun 27, 2017 6:33 pm Post subject: E03 |
|
|
In some of these printers the main gears would get worn badly.
I have the KIP Bulletin Tips K103IPS
It explains how to replace the plastic gears in drive system... Not sure this is causing your problem but...I can send it to you if needed |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Fri Jun 30, 2017 11:06 am Post subject: |
|
|
Have you swapped out the Power supply or just tested it?
I just had a 7900 that was giving E-03 and E-07 errors intermittently 4-5 times during the day. Turns out the was something wrong with one the power supplies. I swapped both at the same time so I'm not sure which one was the culprit, but I haven't been back. |
|
|
|
|
|
|
|
|
|
|
caltech doctor
Joined: 24 Feb 2006 Posts: 262 Location: Northern California |
Posted: Fri Jun 30, 2017 11:40 am Post subject: |
|
|
Unbelievable! It was the braded steel ground wire that grounds the main frame to the movable process unit. It was broken and just needed to be taped together. |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Fri Jun 30, 2017 2:18 pm Post subject: |
|
|
Evil static _________________ Regards,