Joined: 07 Nov 2006 Posts: 1459 Location: E. Syracuse NY |
Posted: Wed Sep 30, 2009 9:20 am Post subject: E-02 in the morning |
|
|
I have a machine that will throw an E-02 every single morning when turning it on. The users will just shut it down for a min. and turn it back on and it goes away until the next morning. I've checked everything within the service manual and everything looks good. Has anyone else seen this issue? I'll have to catch it in the morning to really diagnose it, but is kinda complicated when the issue doesn't happen more than once every morning. |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Wed Oct 29, 2014 11:27 am Post subject: |
|
|
Did you ever find a solution for this? |
|
|
|
|
|
|
|
|
|
|
dlee doctor
Joined: 07 Nov 2006 Posts: 1459 Location: E. Syracuse NY |
Posted: Wed Oct 29, 2014 5:01 pm Post subject: |
|
|
It's been a while but I was able to dig up the call report. It looks like my other tech replaced both of the thermistors (9000290105 and 9000290106). |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Wed Oct 29, 2014 6:39 pm Post subject: |
|
|
Was just curious. Have a friend who is getting E-02 every morning on a 9000. Turn the machine off and back on and it works all day.
Replaced all the thermistors and thermostats. Issue is still there. |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Thu Oct 30, 2014 11:04 am Post subject: |
|
|
Both heat lamps firing? _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
GRAPHICS-TECH medical school freshman
Joined: 04 Jun 2014 Posts: 27
|
Posted: Thu Oct 30, 2014 12:08 pm Post subject: |
|
|
relay |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|