Home of the Kip Doctor!
REGISTER: In order to register for our forums please send an E mail to [email protected] stating what user name and password you would like. This is now required due to all the spambots that have been registering.
|
KeepItPrinting.com The "unofficial' and "unauthorized" KIP info site.
|
|
|
|
|
|
|
|
|
|
|
KipCody medical school grad
Joined: 16 Jul 2013 Posts: 65 Location: Knoxville, TN |
Posted: Fri Oct 24, 2014 3:14 pm Post subject: No Toner, but there is toner |
|
|
I've got an 8000 that constantly gives a no toner message, yet when you go to change the toner the bottle is half full. Does anyone have any ideas on what could be doing this? I have another 8000 for parts that I know worked fine before we took it out of service. So I have no problem swapping stuff out. Just looking for a starting point. |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Fri Oct 24, 2014 5:29 pm Post subject: |
|
|
Check the toner sensors on the hopper and in the developer. |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Fri Oct 24, 2014 6:29 pm Post subject: |
|
|
Someone here had a clogged toner drop between the cartridge and the hopper, might want to check that also. _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
GRAPHICS-TECH medical school freshman
Joined: 04 Jun 2014 Posts: 27
|
Posted: Mon Oct 27, 2014 9:40 am Post subject: |
|
|
check 98
Toner Supply Motor 2
Control Signal (Hopper to
Developer) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
You cannot post new topics in this forum You cannot reply to topics in this forum You cannot edit your posts in this forum You cannot delete your posts in this forum You cannot vote in polls in this forum
|
|
|
|