Posted: Tue Mar 25, 2014 4:11 pm Post subject: error number CE51? |
|
|
A new customer has called in about error code CE51 on a 3100, I can not find this error code in my manuals. Am I just not looking in the correct area?
Does anyone know what this code is for or if it is even a code?
I know that the 5000 model has an error code E-51 with a C to denote the problem, but can not find it for the 3100.
Thanks for any help. |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Tue Mar 25, 2014 5:23 pm Post subject: |
|
|
CE-51 is that shown on the touch screen?
Take the little door off the Service Panel. It will give you the correct error on the LCD screen.
It will probably show either a
E-31 Image Corona Error (Main Charge Wire)
E-32 Separation Corona Error (Separation Wire)
E-33 Transfer Corona Error (Transfer Wire)
Above errors try replacing the wire and cleaning the assy.
Usually this fixes the error.
E-34 Bias Output Error (Developer Bias Issue) See service manual and TB's can walk you through this one. |
|
|
|
|
|
|
|
|
|
|
Tinne73 medical school grad
Joined: 21 Feb 2014 Posts: 54
|
Posted: Tue Apr 01, 2014 1:28 pm Post subject: |
|
|
Thank You, it did end upbeing the Image corona error. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|