Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Mon Mar 10, 2014 10:07 am Post subject: Worm Deletions on 3000 |
|
|
The machine had some other problems like pulling the paper too fast through the fuser so i turned the fuser speed down to take care of that. I replaced the media. The worm deletions are still there. I replaced the transfer and separation wires. Also the image wire. Still getting the deletions like worms on the last half of the drawing. These are oversize 36x60 prints. It is better now but still getting these worm deletions. Anyone know if its just humidity? |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Mon Mar 10, 2014 1:36 pm Post subject: |
|
|
Could be humidity....How miles on the pressure roll? You may also need to put a slight bow (up) in the fuser entrance guide. _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Mon Mar 10, 2014 1:47 pm Post subject: |
|
|
700000+ miles |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Mon Mar 10, 2014 2:31 pm Post subject: |
|
|
Then you need to rotate em buddy........ _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Mon Mar 10, 2014 3:09 pm Post subject: |
|
|
I put another fuser in and did the ssame thing. So not sure if its that. |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Mon Mar 10, 2014 4:46 pm Post subject: |
|
|
You don't mention that you put a fresh roll of paper in.....In any case if you swapped fusers then it stands to reason that the issue is probably not the fuser . I've had a couple of similar problems on other printers that turned out to be the plastic guides on the TS loose or out of position. _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Mon Mar 10, 2014 5:24 pm Post subject: Re: Worm Deletions on 3000 |
|
|
Nathan_Snapper wrote: |
I replaced the media. |
I did mention. I didn't say paper though. I used a snooty term lol. I dind't check the blocks or the caps. or the drum blocks. There hasn't been a change of drum on there. It has a scratch in the middle and has mad bad prints for a while now. |
|
|
|
|
|
|
|
|
|
|
mark in vegas doctor
Joined: 20 Oct 2010 Posts: 1852 Location: Las Vegas, NV |
Posted: Mon Mar 10, 2014 5:34 pm Post subject: |
|
|
Media isn't snooty I just can't read with much comprehension. I'm reffering to the plastic guides covering the separation wire not the blocks. Just something to check until the cause of your misery is found. My misery was caused by two ex wives............. _________________ Regards,
Mark
RVN 68-69
It's so nice to be insane
No one asks you to explain |
|
|
|
|
|
|
|
|
|
|
dlee doctor
Joined: 07 Nov 2006 Posts: 1459 Location: E. Syracuse NY |
Posted: Tue Mar 11, 2014 10:06 am Post subject: |
|
|
Which fuser motor speed did you change? There are 3 motor speeds (settings on No. 070 to 075). Do you have a KIP3000 Service Manual. I have version E.2 and on page 8-61, it shows the defective image (white void) and crease of paper. It explains how to set the motor speeds (including motor speed switch timing). I found that slowing down the speed for 2nd and 3rd fuser speed and the 2nd and 3rd switch timing helped, although you'll have to do trial and error on exact adjustments. |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Wed Mar 12, 2014 10:13 am Post subject: |
|
|
Sounds good I will try that. Thank you. I did do the fuser speeds. I didn't do the switch timing. |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Wed Mar 19, 2014 3:50 pm Post subject: |
|
|
Got another conundrum. The paper isn't wrinkling at the fuser its out of the drawer. |
|
|
|
|
|
|
|
|
|
|
dlee doctor
Joined: 07 Nov 2006 Posts: 1459 Location: E. Syracuse NY |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Wed Mar 19, 2014 5:03 pm Post subject: |
|
|
Thank you that is a load off my mind. |
|
|
|
|
|
|
|
|
|
|
Nathan_Snapper doctor
Joined: 08 Oct 2008 Posts: 274
|
Posted: Sun Apr 13, 2014 8:22 pm Post subject: |
|
|
I fixed this with some rubber rejuvinator on the feed rollers from the drawer and in the first part of the feed into the trnsfer/sep unit. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|