ssbmi medical school freshman
Joined: 14 Jun 2011 Posts: 24 Location: pacific |
Posted: Mon Oct 22, 2012 8:11 pm Post subject: |
|
|
THNAKS FOR ALL YOUR HELP! PROBLEM SOLVED I ADDED A SPACER FOR THE REGULATION ROLLER PRESSURE SPRING TO INCREASE PRESSURE NOW ITS WORKING FINE. HOPE THIS DOES'NT CAUSE ANY OTHER PROBLEMS??? _________________ thank you. |
|
|
|
|
|
|
|
|
|
|
RMS intern
Joined: 05 Sep 2006 Posts: 111
|
Posted: Tue Oct 23, 2012 2:03 pm Post subject: |
|
|
I had this same issue and it was the regulation roller plate on the right side. the bearing on that side was worn & by replaceing it fixed the problem. If you arm having to put more pressure or adding a spacer, check that bearing. I will bet 100% that is your problem. |
|
|
|
|
|
|
|
|
|
|
ubpc medical school freshman
Joined: 18 May 2006 Posts: 28 Location: Waco, TX |
Posted: Tue Nov 20, 2012 5:17 pm Post subject: electric current |
|
|
Looks like a short, check all your contacts |
|
|
|
|
|
|
|
|
|
|
dlee doctor
Joined: 07 Nov 2006 Posts: 1459 Location: E. Syracuse NY |
Posted: Wed Nov 21, 2012 11:27 am Post subject: |
|
|
Did you ever resolve this? |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|