KIP Dude resident
Joined: 14 Feb 2006 Posts: 164 Location: Outside USA |
Posted: Wed Feb 15, 2006 1:05 am Post subject: Toner Dumping |
|
|
I have a 3000 that is continually dropping toner on the left side. I have read the memo on the gear tension... triple checked it... didn't change. I've rebuilt the dev. unit as per previous KIP units... didn't work. It started from day one, so I'm thinking I may have a dead unit.... anybody else have this issue?? _________________ Everytime something is made idiot proof... the world creates a better idiot! |
|
|
|
|
|
|
|
|
|
|
Neil Johnston doctor
Joined: 23 Dec 2005 Posts: 402 Location: Seattle, WA |
Posted: Wed Feb 15, 2006 2:30 am Post subject: |
|
|
I've seen this twice. Both times I fixed it by removing the metal gear and pin then loosening the brass screw. Put a solid downward pressure on the shaft (reg roll) WHILE you tighten the brass screw up. The pressure from the spring is not enough. Put the pin and gear back on. |
|
|
|
|
|
|
|
|
|
|
KIP Dude resident
Joined: 14 Feb 2006 Posts: 164 Location: Outside USA |
Posted: Fri Feb 17, 2006 10:57 pm Post subject: |
|
|
All my other 3000's work fine, I've loosened and tightened that damb assembly several times, even had my other two tech's try it. Same thing every time. Still baffled. _________________ Everytime something is made idiot proof... the world creates a better idiot! |
|
|
|
|
|
|
|
|
|
|
kiptech Guest
|
Posted: Sat Feb 18, 2006 12:35 am Post subject: 3000 |
|
|
You might try releasing the pressure on the rollers then,vacuuming out the unit completely, making sure to get between the regulation roller and the developer roll.
Then repressurize the roller and add toner.
I helped me when I had the exact issue on an 3000. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|