Charlie Brown doctor
Joined: 09 Aug 2005 Posts: 434 Location: Nashville Tennessee |
Posted: Mon Jan 18, 2010 4:09 pm Post subject: Kip 1030 |
|
|
My boss has got a phone call from someone with a Kip 1030 and there telling him they need repair the auger spring in the toner hopper is busted I have no parts manual just a service I need someone to give me part number or tell me this machine parts are no longer in proctuction. _________________ Charlie
I'll keep my Guns, Freedom, & Money ...... YOU CAN KEEP THE "CHANGE!"
I love my grandkids and My Country
I just don't love what my Govt is doing to MY COUNTRY |
|
|
|
|
|
|
|
|
|
|
CHILLIN doctor
Joined: 05 Oct 2006 Posts: 950
|
Posted: Mon Jan 18, 2010 6:44 pm Post subject: |
|
|
The main auger spring in the hopper is Part # 3626A-4 Toner Sender Coil
The big spring that sits on top of it is Part # 3636A-5 Hopper Coil
Not sure if they are still available since they are not listed in the parts manual, but probably still are. |
|
|
|
|
|
|
|
|
|
|
phan6622 doctor
Joined: 09 Feb 2007 Posts: 750 Location: Midwest |
Posted: Mon Jan 18, 2010 7:14 pm Post subject: |
|
|
Its the same as an Oce 7000.. jsut for reference... if you have an outlet for those parts. |
|
|
|
|
|
|
|
|
|
|
caltech doctor
Joined: 24 Feb 2006 Posts: 262 Location: Northern California |
Posted: Tue Jan 19, 2010 1:28 pm Post subject: |
|
|
I’ve worked on a lot of these over the years. I’ve never seen the Toner Spring break but I have seen the Waste Toner Sender Screw come loose several times. This happens when the waste toner backs up for whatever reason and you usually just need to remove the cleaner unit and clean it out and put the spring back together. Unfortunately when this happens the spring usually contacts the drum and damages it. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|