lead guitarist intern
Joined: 03 Apr 2007 Posts: 123 Location: Texas |
Posted: Thu May 31, 2007 1:53 pm Post subject: 2200 scanner problem |
|
|
Hello everyone,
I have a 2200 scanner with a 214 code(platen or glass is dirty)
This started out as an intermitent problem but now has become constant.
Read through Kip manuel reseated all cables led lamps come on(briefly) but the exposure lamps do not "I don't know if they are supposed to at start-up but every other scanner I have ever worked operated with the lamps lit at least for a short time "
I did replace the relay pwb and still nothing. I cannot even get to the basic screen to enter diagnostics. Any ideas what I'm I missing?
John D. Beckerley
A.K.A. Lead Guitarist _________________ If it's too LOUD get some plugs!! |
|
|
|
|
|
|
|
|
|
|
cezwhat resident
Joined: 24 Aug 2005 Posts: 221 Location: On the Prairie |
Posted: Thu Jun 04, 2009 1:45 pm Post subject: |
|
|
did you find a fix for this condition? |
|
|
|
|
|
|
|
|
|
|
lead guitarist intern
Joined: 03 Apr 2007 Posts: 123 Location: Texas |
Posted: Thu Jun 04, 2009 2:02 pm Post subject: 2200 scanner trouble |
|
|
I replaced the main board. Expensive yes, But that was the culprit.
Lead Guitarist _________________ If it's too LOUD get some plugs!! |
|
|
|
|
|
|
|
|
|
|
cezwhat resident
Joined: 24 Aug 2005 Posts: 221 Location: On the Prairie |
Posted: Thu Jun 04, 2009 2:05 pm Post subject: |
|
|
that sucks, thank you for the prompt response |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|